ISO 16701:2015

本頁面標(biāo)準(zhǔn)信息均來源于網(wǎng)絡(luò)收集,或由參與標(biāo)準(zhǔn)制定的供應(yīng)商提供,只作為參考使用,為確保測試結(jié)果的準(zhǔn)確性、節(jié)省您的時間,如需ISO 16701:2015標(biāo)準(zhǔn)詳細(xì)信息或ISO 16701:2015具體測試方法,請與我們技術(shù)人員聯(lián)系或給我們留言,我們將為您提供相關(guān)的技術(shù)支持。

 

ISO 16701:2015英文簡介

Atmospheric corrosion of metallic materials, with or without corrosion protection, is influenced by many environmental factors, the importance of which might vary with the type of metallic material and with the type of environment. It is therefore not possible to design a laboratory corrosion test in such a way that the full complexity of real in-service conditions are taken into account. Acceleration (forced conditions) as such can also have a negative impact on the correlation to field performance. Nevertheless, tests with humidity cycling and only intermittent exposure to salt solution will generally provide a better correlation to field performance than tests using continuous salt spray.

This International Standard was developed in the automotive context, where the major contributor to corrosion is the use of winter time de-icing road salt in cool/cold temperate areas around the world, here as sodium chloride compounds acting in cyclic humidity conditions. The test procedure is moderately forced by humidity and salt and intended to be applicable for quality assurance of the metals and corrosion protections typically encountered in motor vehicles. The method can have relevance also in other areas of application, provided representing similar climatic conditions with an influence of sodium chloride compounds.

1 Scope

This International Standard specifies the test method, the reagents, and the procedure to be used in an accelerated atmospheric corrosion test constituting a 6 h exposure to a slightly acidified solution of 1 % NaCl twice weekly, followed by a condition of controlled humidity cycling between 95 % RH and 50 % RH at a constant temperature of 35 °C.

This International Standard does not specify the dimensions of the tests specimens, the exposure period to be used for a particular product, or the interpretation of the results. Such details are provided in the appropriate product specifications.

The accelerated laboratory corrosion test applies to

— metals and their alloys,

— metallic coatings (anodic or cathodic),

— chemical conversion coatings, and

— organic coatings on metallic materials.

NOTE 1 If testing low-alloy stainless steels, especially austenitic grades, according to this International Standard, there is a risk of receiving exaggerated pitting, not representative for most service environments.

NOTE 2 This International Standard is not suitable for testing of wax and oil based rust protection agents, due to the constantly elevated temperature condition of the test.

2 Normative references

The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

ISO 4628-1, Paints and varnishes — Evaluation of degradation of coatings — Designation of quantity and size of defects, and of intensity of uniform changes in appearance — Part 1: General introduction and designation system

ISO 4628-2, Paints and varnishes — Evaluation of degradation of coatings — Designation of quantity and size of defects, and of intensity of uniform changes in appearance — Part 2: Assessment of degree of blistering

ISO 4628-4, Paints and varnishes — Evaluation of degradation of coatings — Designation of quantity and size of defects, and of intensity of uniform changes in appearance — Part 4: Assessment of degree of cracking

ISO 4628-5, Paints and varnishes — Evaluation of degradation of coatings — Designation of quantity and size of defects, and of intensity of uniform changes in appearance — Part 5: Assessment of degree of flaking

ISO 8407, Corrosion of metals and alloys — Removal of corrosion products from corrosion test specimens

ISO 10289, Methods for corrosion testing of metallic and other inorganic coatings on metallic substrates — Rating of test specimens and manufactured articles subjected to corrosion tests

kingjo-FOG CRH鹽霧試驗箱用于ISO 16701:2015的測試方法

HONGZHAN-FOG CRH鹽霧試驗箱用于ISO 16701:2015的測試方法

kingjo-FOG CRH鹽霧試驗箱用于ISO 16701:2015的測試方法

聯(lián)系人
在線客服
用心服務(wù) 成就你我

粵公網(wǎng)安備44190002001386號

主站蜘蛛池模板: 中文无码人妻有码人妻中文字幕 | 天天影视性色香欲综合网| 亚洲精品一区二区三区中文字幕| 久久久精品波多野结衣| 国产成人精品.视频| 亚洲精品国产品国语原创| 大香网伊人久久综合网2018 | 国产曰批免费视频播放免费 | 极品少妇被猛的白浆直喷白浆| 97在线视频人妻无码| 精品麻豆一区二区三区乱码| 久久www成人影院| 亚洲精品久久久狠狠爱小说| 大伊香蕉精品视频在线天堂| 国产av成人精品播放| 亚洲精品国男人在线视频| 国产波霸爆乳一区二区| 精品久久久久国产免费| 18禁无遮挡羞羞污污污污免费| 137肉体摄影日本裸交| 绝顶丰满少妇av无码 | 一本加勒比hezyo无码资源网| 久热这里只精品99国产6-99re视…| 欧美亚洲日本日韩在线| 色婷婷香蕉在线一区二区| 亚洲小说区图片区另类春色| 国产精品jk白丝在线播放| 射精区-区区三区| 亚洲 欧美 偷自乱 图片| 国产精品性夜天天拍拍2021| 日本乱码一区二区三区不卡| 日韩av无码一区二区三区不卡 | 久久天天躁狠狠躁夜夜av浪潮 | 四房播播开心五月| 最新精品露脸国产在线| 中文字幕无码精品亚洲资源网久久 | 国产超碰人人做人人爱| 免费裸体美女网站| 18禁黄无遮挡网站免费| 国产成+人欧美+综合在线观看| 日韩激情无码不卡码|