1. SCOPE

This standard specifies accelerated test method for light resistance (*1) of non-metallic materials and products in automobile cabin using light-exposure apparatus with xenon-arc lamp (*2) (hereinafter call “Test apparatus”).

Note:

(*1) The property of resistance to variation of color, gloss, etc. under irradiation of light, and shall be distinguished from weather resistance, which is the property of resistance to variation to natural actions, such as out-door sunlight, wind, rain, etc.

(*2) Test apparatus capable of performing irradiation of an artificial light source closely resembling sunlight for examining part of the properties of light resistance in a short time.

2. DEFINITION OF TERMS

Definitions of main terms used in this standard shall be accordance with Table 1.

Table 1

Term

Definition

1)       Black panel temperature

(hereinafter call “B.P.T”)

The temperature indicated by a black panel thermometer attached to a rack or rotary board, which is representative for the surface temperature of test pieces.

2)       Xenon-arc lamp

An arc lamp which emits by xenon-arc discharge.

3)       Emission part

The part composed of a xenon-arc lamp and a filter.

3.TSET CONDITIONS

For evaluating variation of color, gloss, etc., conditions, such as temperature, humidity, irradiance, etc., which are effective on test results, shall be in accordance with Table 2.

Table 2

Item

Condition

1)       Temperature

B.P.T. 89±3%

2)       Relative humidity

50±5%RH

3)       Irradiance(*3)

48-100W/m2(within 300-400nm)

4)       Irradiance ratio

Irradiance of 320nm max. shall be under 1.5% of that of 300-400nm

5)       Irradiation method

Continuous irradiation

6)       Test period control

According to radiant exposure quantity

Note(*3): Selection of irradiance shall be effective on acceleration, however, irradiance also shall be effective on sample temperature and heat history. Appropriate irradiance is needed to be selected considering effect on sample by temperature.

4. APPARATS AND PERFORMANCE

Test apparatus shall be constructed of an emission part, xenon-arc starting and stabilizing apparatus, irradiance adjusting apparatus, temperature adjust apparatus, test tank, humidity adjusting apparatus, test piece holder, cooling apparatus, instrumentation apparatus, etc.

4.1 Emission Part

4.1.1 Emission Part shall be as follows, according to clause 3:

1) Xenon-arc lamp: Xenon-arc lamps are long arc lamps of a.c. burning in which electrodes are sealed-in both ends of a quartz tube and xenon gas is sealed-in inside, and are used with performing forced water cooling or forced air cooling.

2) Filter: Filters are used for obtaining the required spectral characteristics and for cooling the xenon-arc lamp. For insulating the ultraviolet part, glass filters for ultraviolet-radiation insulation, running water, etc., are used.

3) Other: Based on the portion to be used, material superior in heat resistance, corrosion resistance, humidity resistance, or electric insulation shall be used.

4.1.2 Spectral characteristics of emission part

The xenon-arc lamp shall have a continuous spectrum at least over the wavelength range of 250 to 1200 nm, and shall have a similar spectral characteristics to glass-through-sunlight in combination with filter.

4.1.3 Irradiance of test piece surface

Irradiance of test piece surfaces shall be able to be set on any certain value within 48-100W/m2 at least over the wavelength range of 300 to 400 nm.

Also, spectral irradiances of test piece surfaces in the wavelength of 300 to 400nm shall be indicated for each type of test apparatus. Further, the irradiance in other wavelength ranges or the spectral irradiance at s specific wavelength should also be marked upon agreement between the parties concerned. The measuring method is to be in accordance with the annex of JIS B 7754.

4.1.4 Tolerance in irradiance during operation

It shall be capable of maintaining ±10% of the set irradiance.

4.1.5 Tolerance in irradiance of test pieces surfaces

The difference of irradiances of test piece surfaces due to the position must not exceed 10% of the maximum value.

4.1.6 Irradiation method

As a rule, a certain constant irradiance shall be kept continuously during operation.

4.2 Irradiance Adjusting Apparatus

The irradiance adjusting apparatus is an apparatus to correct the attenuation of radiation energy accompanying the use of a xenon-arc lamp and filter, measuring the irradiance in the wavelength of 300 to 400 nm, and shall be provided with one of the following conditions:

1) It shall be capable of manual adjustment of the lamp power to make the irradiance constant.

2) It shall be capable of automatic control of the lamp power to make the irradiance constant.

3) It shall be capable of manual adjustment of the lamp power stepwise accoding to the time of use.

4.3Black Panel Thermometer

Black panel thermometer is so structured that the heat sensitive body, bimetal, platinum resistor, thermistor, thermoelectric couple, etc., is attached coincident with the center of the metal plate and is adhered tightly to the heat sensitive body protecting tube.

Remarks: Structures and dimensions shall be in accordance with 5.7(2) and Attached Fig.1. Type A of JIS B 7754.

4.4 Test Tank

Temperature and humidity in test tank shall be as follows:

1) B.P.T. at the position of test piece shall be 89±3℃.

Remarks: Temperature will be different depending on the combination of xenon-arc lamp type and filter.

2) Relative humidity

It shall favorably be capable of keeping relative humidity 50±5% under the temperature specified in 1). Further, relative humidity shall be measured at the point close to and inside the exit of test tank.

4.5 Other

Items unspecified in the foregoing clauses, such as test tank, xenon-arc starting and stabilizing apparatus, temperature adjusting apparatus, humidity adjusting apparatus, test piece holder, cooling apparatus, instrumentation apparatus, etc., shall be in accordance with JIB B 7754.

5. TEST PIECE

5.1Dimensions of Test Piece

Irradiation area of test piece shall be 30 mm min in vertical direction and over 30mm min horizontal direction, and thickness shall be determined according to agreement to agreement between the parties concerned. Further, when test piece has urethane foam backing layer as part construction, density and composition, etc. of the layer shall be determined between the parties concerned.

5.2 Other

In case of test piece with texture direction, such as fabrics, etc., attachment direction relative to test apparatus shall be indicated.

6. PROCEDRE

6.1 Attach test piece on test piece holder firmly so that it won’t drop. Further, when backing material like urethane foam is attached on backside of test piece, the backside shall be contracted with backing material as tightly as possible so that it shall not become loose.

6.2Set test piece holders with test pieces attached on a rack or a rotary board without gaps between the holders. When there are some test piece holders without test pieces, put white-colored papers, aluminum plates, stainless steel plates, etc., on all of the holder in order to keep heat equilibrium inside test tank.

6.3 Select a certain irradiance within 48-100W/m2 in the wavelength of 300-400nm, and adjust test apparatus so that the selected irradiance shall be kept constant during exposure.

6.4 Adjust B.P.T during exposure within 89±3℃ by temperature adjusting apparatus.

6.5 Adjust humidity during exposure within 50±5% RH.

6.6 In case of broad samples, their position shall favorably be replaced at certain intervals for better test accuracy.

Remarks: Radiant exposure quantity can be calculated by the following formula:

Radiant exposure quantity (KJ/m2) = Irradiance (W/m2)×Time(Hr)×3.6

Applicable standards

JIS B 7754

JASO M 346

Reference Standard

 

<

Applicable Standard

 

<

 

上一篇:HG/T 2006-2006

下一篇:GMW14872-2013

返回列表>>
聯系人
在線客服
用心服務 成就你我

粵公網安備44190002001386號

主站蜘蛛池模板: 色综合伊人色综合网站无码| 亚洲精品无码专区在线观看| 中文字幕精品视频在线看免费| 国产拍揄自揄精品视频| 国产成人免费一区二区三区| 日韩视频在线观看| 亚洲欧美国产双大乳头| 久久亚洲道色综合久久| 国产av巨作丝袜秘书| 中文字幕在线播放| 中文精品无码中文字幕无码专区| 少妇高潮太爽了在线视| 色老99久久精品偷偷鲁| 国产卡一卡二卡三| 国产精品乱码一区二区三| 一本久久伊人热热精品中文字幕| 国产婷婷丁香五月缴情成人网| 天堂中文а√在线官网| 色偷偷88888欧美精品久久久| 久久熟妇人妻午夜寂寞影院| 国产高清视频在线观看97| 欧美日韩一区二区三区在线观看视频| 999zyz玖玖资源站永久| 人妻精品制服丝袜久久久| 午夜人性色福利无码视频在线观看 | 亚洲欭美日韩颜射在线二| 日本少妇被黑人xxxxx| 久久亚洲国产精品123区| 乱人伦中文无码视频| 亚洲中文字幕无码中文字在线 | 亚洲最大成人综合网720p| 激情97综合亚洲色婷婷五| 国产精品久久久久久人妻精品| 中文字幕人成无码人妻| 国产精品久久久久久免费软件| 亚洲精品图片区小说区| 人与嘼交av免费| 日韩a无v码在线播放| 日韩人妻少妇一区二区三区| 国产成人a视频高清在线观看| 中文成人无码精品久久久不卡|