本頁面標(biāo)準(zhǔn)信息均來源于網(wǎng)絡(luò)收集,或由參與標(biāo)準(zhǔn)制定的供應(yīng)商提供,只作為參考使用,為確保測試結(jié)果的準(zhǔn)確性、節(jié)省您的時間,如需FLTM BO 116-01_2007標(biāo)準(zhǔn)詳細(xì)信息或FLTM BO 116-01_2007具體測試方法,請與我們技術(shù)人員聯(lián)系或給我們留言,我們將為您提供相關(guān)的技術(shù)支持。

 

FLTM-BO-116-01標(biāo)準(zhǔn)簡介

FLTM-BO-116-01 汽車內(nèi)飾材料暴曬試驗標(biāo)準(zhǔn):水冷式氙弧燈氣候試驗箱方法

FLTM  BO 116-01_2007標(biāo)準(zhǔn)英文版

EXPOSRE OF INTERIOR TRIM MATERIALS IN A CONTROLLED IRRADIANCE

WATER COOLED XENON-ARC APPARATS

Application

This procedure is used to determine the effects of simulated weather on interior trim materials using a controlled irradiance water cooled xenon-arc Weather-Ometer® with an auxiliary lantern and filters.

Apparatus Required

Operating Filter

335 nm long pass filters (SF-5 filters) or equivalent provided the transmission spectrum is within 95% of the SF-5 filter transmission at all wavelengths. The filters are reversible unless otherwise marked by a coating or etching.

Dimensions for the Ci 5000 series Weather-Ometer®:

339 mm +/- 0.13 mm x 70 mm +/- 0.13 mm x 3 mm +/- 0.52 mm

Dimensions for the Ci 3, Ci 6 & Ci 4000 Weather-Ometer®:

220 mm +/- 0.13 mm x 70 mm +/- 0.13 mm x 3 mm +/- 0.52 mm

Lamp Sensor Irradiance Filter

420 nm Irradiance Filter

Available from:

Atlas Material Testing Technology LLC

4114 Ravenswood Ave.

Chicago, IL 60613 SA

Calibration Lamp

The calibration lamp must be calibrated to 420 nm with the lantern assembly removed.

Available from:

Atlas Material Testing Technology LLC

4114 Ravenswood Ave.

Chicago, IL 60613 SA

Sample & Test Conditions

Sample Conditioning

All test values indicated herein are based on material conditioned in a controlled atmosphere of 21 +/-2 °C and 50 +/- 5% relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified.

Test Conditions

Testing conditions such as black panel temperature, dry bulb temperature, humidity, light cycle times and dark cycle times are equivalent to those outlined in SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Table 1,Section 6.1.5.

Place the 335 nm long pass filters (SF-5 filters) or equivalent into the auxiliary lantern. Orient thelantern around the xenon-arc lamp assembly which is equipped with the Quartz/Type "S" Borosilicate filtered xenon-arc lamp source as outlined in SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Apparatus Set-p, Section 6.

Exposures are monitored based on measured light at 1.06 W/m2 -/nm@420 nm SAE J2412 –Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance XenonArc Apparatus, Table 1.

Calibration

Equipment Calibration

As per SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Appendix A, Section A.3 and Appendix B.

Maintenance

Equipment Maintenance

As per SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Appendix A.

Note: SF-5 auxiliary filters should be cleaned at every lamp calibration period or more frequent if necessary.

SF-5 filters and the 420 nm interference filter should be changed per the manufacturer's recommendations/or within 13,000 hours of use.

Exposure

Sample Exposure

As per SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Test Procedure, Section 7.

Evaluation & Reporting

Sample Evaluation and Exposure Report

As per SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Evaluating and Reporting, Section 8 and Exposure Report, Section 9.

AATCC Gray Scale, 10 Step, According to AATCC Evaluation Procedure 1/ISO 105-A02 for Evaluation of Color Change.

FLTM BO II--01_2007測試機構(gòu)

 

pon request measure the gloss with a 60° glossmeter (or as specified in the applicable Engineering Standard) according to FLTM BI 110-01. Record the unexposed and exposed gloss.

Chemicals, materials, parts and equipment referenced in this document must be used and handled properly. Each party is responsible for determining proper use and handling in its facilities.

上一篇:GB 16776-2005

下一篇:ETAG 002-1999

返回列表>>
聯(lián)系人
在線客服
用心服務(wù) 成就你我

粵公網(wǎng)安備44190002001386號

主站蜘蛛池模板: 久久不见久久见免费影院视频| 亚洲中文字幕婷婷在线| 东京热毛片无码dvd一二三区| 人人妻人人爽人人添夜夜欢视频 | 一区二区视频传媒有限公司| 亚洲精品中文字幕乱码4区| 影视av久久久噜噜噜噜噜三级| 国产sm重味一区二区三区| 四虎影视永久地址www成人| 国产精品白丝av在线观看播放| 国产高潮流白浆视频| 国产精品免费大片| 国产成人一区二区三区别| 色综合久久久久综合99| 日本乱亲伦视频中文字幕| 久久精品国产精品亚洲艾草网| 性夜夜春夜夜爽aa片a | 国产精品揄拍100视频| 日日摸天天摸爽爽狠狠97| 天天做av天天爱天天爽| 久久国产人妻一区二区| 精品久久久无码人妻中文字幕| 国产成人麻豆精品午夜福利在线| 久久久久中文伊人久久久| 精品人妻va出轨中文字幕| 狠狠色噜噜狠狠狠狠av| 98久久人妻少妇激情啪啪| 99热这里只有是精品2| 一个人看的免费视频www中文字幕| 和岳每晚弄的高潮嗷嗷叫视频| 亚洲性夜夜综合久久7777| 亚洲成av人片在线观l看福利1| 久久久久黑人强伦姧人妻| 亚洲色自偷自拍另类小说| 无码人妻天天拍夜夜爽| 日本爽爽爽爽爽爽在线观看免 | 免费能直接看黄的视频| 欧美性猛交久久久乱大交小说| 性生交大全免费看| 无码一区二区三区老色鬼| 国产在线拍揄自揄拍免费下载 |